three wavelength laser hair removal equipment

Store the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG equipment options 3 wavelengths (755, 808, 1064nm) for painless hair elimination.
two-in-one Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Equipment
Achieve Skilled-grade benefits While using the Soprano Titanium Ice Platinum, a robust two-in-one technique combining 3-wavelength diode laser technological innovation for painless hair removal and a Q-Switched ND:YAG laser for tattoo removing and pores and skin rejuvenation. Equipped with a 4000W superior-ability motor and five-level adjustable cooling technology, this CE-Accredited machine delivers Protected, economical, and everlasting outcomes for all skin styles and entire body spots.

Hair Removal: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Skin Correction: Q-Switched ND:YAG for tattoo elimination and carbon peeling
Comfort: 5-Level adjustable cooling technique for just a pain-free encounter
Electrical power: 4000W significant-Electrical power density with German Diode Arrays

Vital Features
three-Wavelength Diode Technological know-how: Integrates 755nm (Alexandrite), 808nm (Velocity), and 1064nm (YAG) wavelengths into one applicator to target various hair depths and buildings concurrently.
Dual-Functionality Process: A true two-in-1 workstation showcasing a devoted Diode laser for permanent hair reduction and also a Q-Switched ND:YAG laser for pigmented lesion remedy and tattoo removing.
Innovative five-Level Cooling: Capabilities the “Titanium Ice” five-level adjustable cooling know-how that retains the sapphire tip at an ideal temperature, guaranteeing the procedure remains cozy and painless.
Substantial Output General performance: Pushed by a large 4000W power supply and German-imported Diode arrays, offering nearly 2000mj energy density for fast and effective scientific effects.
Massive Touchscreen Interface: Outfitted having a high-definition interactive Exhibit for exact control about Vitality ranges, pulse frequency, and cooling depth throughout diverse therapy modes.
Compatibility & Finest Use
Total System Application: Safe and powerful to be used around the experience (higher lip, chin), underarms, bikini line, arms, legs, again, and upper body.
All Pores and skin Kinds: The triple wavelength program is built to do the job effectively on all skin tones (Fitzpatrick scales I-VI) and hair colors, such as good and light hair.
Skin Rejuvenation: get more info Utilize the ND:YAG tackle While using the black doll (carbon) idea for deep pore cleaning, pores and skin whitening, and anti-getting old solutions.
Tattoo & Pigment Elimination: Goal dim and colored inks particularly utilizing the Q-Switch frequency for non-invasive removing of tattoos and freckles.
Installation Recommendations
Water Cooling Set up: This higher-ability laser Laser Hair Removal needs distilled h2o for its cooling method; make sure the h2o tank is filled for the proposed amount prior to powering to the machine for the first time.
Tackle Relationship: Very carefully align the pins on the laser handles Along with the equipment ports and protected the locking system to read more be certain steady signal and cooling fluid transmission.
Voltage Verification: The equipment supports 110V and 220V; make certain your ability outlet matches the particular voltage options in the equipment to circumvent electrical problems.
Parameter Calibration: For new users, it here is usually recommended to begin remedies at the bottom Electrical power settings and slowly maximize based upon the shopper’s skin sensitivity and feed-back.
Item Technical specs
Brand Title emszero
Model Selection Titanium 2-in-one (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Energy Output 4000W
Strength Density Approximately 2000mj (Adjustable)
Cooling Amount 5 Stages Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, fifty/60Hz
Packing Checklist
one x Soprano Titanium 2-in-1 Most important Console (4000W)
one x three-Wavelength Diode Laser Manage
one x Q-Swap ND:YAG Laser Take care of
3 x Specialized ND:YAG Ideas (532nm, 1064nm, get more info 1320nm)
1 x Energy Cable & Foot Pedal
1 x User Manual & Protective Goggles Established

Warnings & Safety Notes
Eye Security: Generally dress in the provided laser-protection goggles through operation to prevent permanent eye harm from stray laser reflections.
Never Operate Dry: Usually do not function the device without having filling it with distilled h2o; managing the laser with no functioning cooling loop will bring about rapid inside components failure.
Contraindications: Usually do not use this device on places with open wounds, active infections, or on people who are pregnant or have mild-sensitive health care disorders.
Cooling Servicing: Change the distilled drinking water every single three months to guarantee The inner pump and laser arrays continue to be free of mineral buildup and overheating.

Leave a Reply

Your email address will not be published. Required fields are marked *